Graham Field LF1050 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Rozmetadlo Graham Field LF1050. Graham Field LF1050 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
LF1050-INS-LAB-RevE13
© 2013 GF Health Products, Inc.
Read this manual before operating your Patient Lift.
Save this manual for future use.
The most current version of this manual can be found online at
www.grahameld.com.
LF1050 PATIENT LIFT
USER MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - USER MANUAL

LF1050-INS-LAB-RevE13 © 2013 GF Health Products, Inc.Read this manual before operating your Patient Lift.Save this manual for future use.The most curr

Strany 2 - CONTENTS

LF1050-INS-LAB-RevE13 109. Attach the spreader bar bracket to the boom and insert retainer pin, as shown above. Insert retaining ring through retainer

Strany 3 - 1 INTRODUCTION

LF1050-INS-LAB-RevE13 11CHARGING THE BATTERIESCharge the batteries after assembly.1. Ensure the battery box power switch is ON (i.e., the red button

Strany 4 - 2 SAFETY PRECAUTIONS

LF1050-INS-LAB-RevE13 126 OPERATING INSTRUCTIONS WARNING: During lifting and lowering, whenever possible, always keep the base legs of the lift in t

Strany 5

LF1050-INS-LAB-RevE13 13Lifting the patient from a bed1. Position patient face-up in center of bed. Roll patient onto their side facing away from you

Strany 6 - 3 FEATURES

LF1050-INS-LAB-RevE13 14Lowering the patient to the oor1. Place a pillow on the base to protect the patient’s head and neck (this is unnecessary whe

Strany 7 - 4 HANDLING PROCEDURES

LF1050-INS-LAB-RevE13 15Transferring the patient from a bed to a wheelchair or commode chair1. For smooth, easy lifting, have the wheelchair or commo

Strany 8 - 5 ASSEMBLY INSTRUCTIONS

LF1050-INS-LAB-RevE13 16EMERGENCY RELEASEIn case of lift failure while using the Lumex LF1050 Patient Lift, follow the procedure below to safely lower

Strany 9

LF1050-INS-LAB-RevE13 177 CARE AND MAINTENANCEProper care and maintenance are essential to keeping your Lumex LF1050 Patient Lift in a safe operating

Strany 10 - Actuator plug

LF1050-INS-LAB-RevE13 18CLEANINGRegular cleaning is recommended every three months; clean the lift more often as needed. A soft cloth, dampened with w

Strany 11 - ALARM BUZZERS

LF1050-INS-LAB-RevE13 198 TROUBLESHOOTINGThe following list of encountered problems and their solutions will assist you in determining what may be ca

Strany 12 - 6 OPERATING INSTRUCTIONS

LF1050-INS-LAB-RevE13 2GF Health Products, Inc. is not responsible for typographical errors. For the most updated and current information on packaging

Strany 13 - LF1050-INS-LAB-RevE13

LF1050-INS-LAB-RevE13 209 SPECIFICATIONSInfo: All dimensions are given in inches unless otherwise specified.Basewidth Open:37.5"Closed:26"

Strany 14

LF1050-INS-LAB-RevE13 2110 LIMITED WARRANTYGF Health Products Inc. (“Graham-Field”) warrants this product to be free from manufacturing defects in ma

Strany 15

LF1050-INS-LAB-RevE13 22THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND IMPLIED WARRANTIES, INCLUDI

Strany 16 - Turn clockwise to lower

LF1050-INS-LAB-RevE13 2311 INDEXAAssembly instructions 8BBefore each use 17CCare and maintenance 17Care of slings 18CAUTION statement, signicanc

Strany 17 - 7 CARE AND MAINTENANCE

GF Health Products, Inc. 2935 Northeast Parkway Atlanta, Georgia 30360 USAtel: 770-368-4700 fax: 770-368-2368www.grahamfield.com

Strany 18 - MAINTENANCE SCHEDULE

LF1050-INS-LAB-RevE13 31 INTRODUCTIONCongratulations on your purchase of the Lumex LF1050 Patient Lift. The following pages will provide you with imp

Strany 19 - 8 TROUBLESHOOTING

LF1050-INS-LAB-RevE13 42 SAFETY PRECAUTIONSIMPORTANT: Before using patient lift, please read and adhere to the following safety precautions and warni

Strany 20 - 9 SPECIFICATIONS

LF1050-INS-LAB-RevE13 5 WARNING: When transferring a patient, always keep the patient centered over the base. WARNING: Ensure that lifting sling loo

Strany 21 - 10 LIMITED WARRANTY

LF1050-INS-LAB-RevE13 63 FEATURESLIFT COMPONENTSa. Boom b. Mast c. Base d. Spreader bar e. Pendant f. Actuator g. Control box h. Caster brake

Strany 22

LF1050-INS-LAB-RevE13 74 HANDLING PROCEDURESSHIPPING AND TRANSPORTATION INSTRUCTIONSIf the patient lift is to be reshipped by common carrier, it shou

Strany 23 - 11 INDEX

LF1050-INS-LAB-RevE13 85 ASSEMBLY INSTRUCTIONS WARNING: The lift is heavy. To avoid personal injury, DO NOT attempt to assemble the lift without ass

Strany 24 - Atlanta, Georgia 30360 USA

LF1050-INS-LAB-RevE13 96. Place the control box in the bracket, as shown above.7. Attach the actuator bottom to the mast bracket and insert retainer

Komentáře k této Příručce